Latching Relay Termination: PCB Solder vs Fast-Connect vs Custom
A meter that switches 80 to 90 A has to decide where that current physically runs. PCB solder, fast-connect terminals and pre-assembled harnesses with copper straps or an integrated shunt all carry the same load, but they place the interfaces in different hands. The relay's electrical ratings change less than the assembly consequences do.
This comparison uses three published GRT Relay integration paths. The GRT508BJ is the PCB-solder reference: a 2-pole latching relay rated 90 A for resistive switching in a 38 × 30 × 16.5 mm envelope. The GRT508BV and GRT508BW are fast-connect examples, both rated 80 A resistive at 250 VAC with 5–24 VDC coils, but with different terminal designs and envelopes. Custom assemblies add flexible wire, copper straps or an integrated shunt to the relay.
The working rule: choose PCB solder when the board already owns the current path and the enclosure is height-limited; choose fast-connect when a harness, busbar or service access decides the architecture; choose a custom assembly when the shunt and wiring should arrive as one qualified item. Each option moves work, inspection and risk between the meter builder and the relay supplier.

Relay production at GRT Relay: standard PCB-solder and fast-connect models and custom assemblies are built inside the same manufacturing operation.
What the termination decision actually controls
A latching relay holds its contact position without continuous coil current, which is why it suits meter disconnect functions: the coil is pulsed to change state and the position is retained afterwards. That behaviour is identical across all three termination paths, so it does not help a builder choose between them.
Three coupling points decide most of the outcome:
- Current path. With PCB solder, current leaves the relay through pins into board copper. With fast-connect, it leaves through a terminal into a wire or busbar. With a custom assembly, it leaves through a conductor the relay supplier has already attached — flexible wire, a copper strap or a shunt. Every interface adds one more place where contact resistance and heat must be controlled.
- Mechanical support. A soldered relay is held by its pins and the board. A fast-connect relay is held by the housing or panel plus the terminal. A custom assembly is held by whatever mounting the assembly drawing defines. Vibration and thermal cycling load the weakest of these.
- Assembly and test ownership. Every interface transferred from the meter builder to the relay supplier removes a step from the meter line, but it also removes a degree of freedom from the builder's own inspection plan.
That is why the same 80–90 A relay can be a good or a poor choice for two meter designs with identical electrical requirements.
Compliance context that shapes the comparison
Two compliance layers frame the decision more tightly than they did a few years ago.
The first is the metering standard itself. IEC 62055-31:2022, published by the International Electrotechnical Commission, defines utilization categories UC2, UC3 and UC4 for latching relays used in payment meters, and the standard's scope covers static payment meters for active energy in classes 1 and 2. A relay that switches a prepaid meter's load therefore has to be discussed in terms of a utilization category, not only an ampere figure.
The reviewed product data does not attach a UC2 statement to the GRT508BJ, GRT508BV or GRT508BW. GRT's published information does include RoHS compliance statements for latching relays and an IEC 62055-31 UC3 compliance statement on one relay entry. That is a portfolio-level picture: category claims have to be confirmed per model, with the supporting declaration requested in the RFQ rather than assumed from a web page.
The second layer is material compliance. Directive 2011/65/EU (RoHS 2) restricts the use of certain hazardous substances in electrical and electronic equipment placed on the EU market, and a relay is an electrical component inside that scope. Separately, IEC 61810-1 provides the general safety framework for electromechanical elementary relays. In practice a meter builder ends up holding three kinds of document: a general relay safety basis, an application-level utilization-category statement, and a RoHS declaration or test report.
Market context is secondary here, but worth one line: research published by MarketsandMarkets in October 2026 projected the global relay market — all relay types, not latching relays alone — growing from USD 11.75 billion in 2026 to USD 15.65 billion by 2031. That figure says nothing about which termination suits a meter design; it only indicates that relay supply remains a scaled, competitive category.
All three reference models come from GRT Relay, the brand of Zhejiang Great Electrical Co., Ltd., a manufacturer established in 2003 and based in Jiashan County, Jiaxing City, Zhejiang Province, whose product scope covers latching relays, miniature current transformers and manganese copper shunts.
Path 1: PCB solder with the GRT508BJ
The GRT508BJ is the PCB-solder reference in this comparison: a 2-pole latching relay rated 90 A for resistive switching, supplied as a PCB soldering type with PCB mounting and an outline of 38 × 30 × 16.5 mm. GRT describes the model as intended for the smart metering industry and designed for smart meter switching, with prepaid meter load switching listed among its typical applications.
The published envelope and endurance figures are what shape a board design. The relay occupies 38 × 30 mm of board area at 16.5 mm height, operates from -40 °C to +85 °C ambient, and is rated for 100,000 mechanical operations. Its stated short-circuit withstand is 2500 A for 10 ms and 4500 A for 10 ms without explosion. That is a statement about the relay surviving a fault event; it does not transfer automatically to board traces or to the meter's internal wiring.
For the builder, the consequences are concrete:
- The 90 A current path includes solder joints and board copper, so trace width, copper weight, via strategy and joint quality become part of the electrical design rather than a downstream detail.
- There is no terminal interface to torque, plate or inspect, which removes one fastening step and one class of loosening-related field failure.
- Rework means desoldering. A relay that fails final test takes board copper with it if removal is rushed.
- 16.5 mm height is compact for a 2-pole, 90 A part, which matters when the terminal block and display stack compete for the same vertical space.
In return, the builder keeps full control of the current path inside its own process. Nothing about the termination is proprietary, and second-source evaluation becomes a question of footprint and pin compatibility rather than of replicating an assembly drawing.

Production workshop: soldered and fast-connect relay variants move through the same manufacturing stages before assembly-level customisation.
Path 2: Fast-connect with the GRT508BV and GRT508BW
The GRT508BV and GRT508BW both use fast-connect installation and share a common electrical envelope: 80 A rated resistive load, 80 A maximum switching current, 250 VAC maximum switching voltage, a 5–24 VDC coil range, AgSnO2 contacts, 4 kV dielectric strength between coil and contacts, an ambient range of -40 °C to +85 °C, 100,000 mechanical operations, and a stated short-circuit withstand of 2500 A for 10 ms and 4500 A for 10 ms without explosion. Both are built from copper and plastic.
The differences explain why two models exist.
The GRT508BV measures 52.5 × 35 × 17.7 mm and uses a T1 in / T4 out terminal design. Its published contact switching capability is 60 A, while its rated resistive load and maximum switching current are 80 A. These numbers are not interchangeable: the 60 A figure describes contact switching capability, the 80 A figures describe the resistive rating and the maximum switching current. A specification that quotes only “80 A” without saying which of the three it means is incomplete.
The GRT508BW measures 55.6 × 30 × 16.5 mm. Against the BV it is 5 mm narrower and 2 mm lower but 3.1 mm longer; against the GRT508BJ it keeps the same 30 mm width and 16.5 mm height while adding 17.6 mm of length. For a meter whose height limit is already fixed by the enclosure, that is a useful trade: the extra volume goes into length, not into the vertical stack.
The BW entry also states a 10,000-operation electrical endurance and confirms that it requires only impulse excitation, for both single-coil and double-coil versions. The BV's reviewed data states 100,000 mechanical operations without publishing an electrical-endurance figure. A buyer comparing BV and BW on switching life can therefore complete the mechanical half of the comparison and cannot complete the electrical half from published data alone.
What the fast-connect path changes for the meter builder: current leaves the relay through a terminal, so terminal plating, clamping force and the mating conductor become part of the 80 A circuit. In exchange, the relay can sit on a housing or busbar, be fitted after the board is soldered, and be replaced without touching a soldered joint. In panel-based meter architectures and in assemblies that must be serviced, that is often the deciding factor.
Path 3: Custom assemblies with wire, straps or an integrated shunt
GRT describes custom latching relay assemblies with flexible wire and/or copper straps and/or an integrated shunt. One entry in its product information, the GRT508FN, states that custom assemblies are available with flexible wires, copper straps or an integrated shunt, with a custom latching relay variant offered within that series. The GRT508FN base entry lists overall dimensions of 98.2 × 40.3 × 37.7 mm, AgSnO2 contacts, copper and plastic construction, fast-connect installation, and impulse excitation for both single-coil and double-coil versions.
An integrated shunt is not an accessory in this context; it is the current-sensing element inside the purchased assembly. GRT's portfolio combines latching relays with miniature current transformers and manganese copper shunts, which is the component set a meter's current-measurement chain needs. Building the shunt, the strap and the relay into one item reduces the number of interfaces the meter builder has to design, purchase and inspect.
The trade-off is specification ownership. Once the shunt sits inside the assembly, the builder no longer controls it as a separate part with its own tolerance and temperature behaviour; it controls an assembly-level requirement instead. The reviewed data does not publish the custom assembly's current rating, shunt resistance tolerance, temperature rise or interface dimensions beyond the base relay envelope, so those values have to be written into the assembly drawing and confirmed on samples.
Custom assemblies also change the supplier relationship. A single sourced assembly concentrates risk: a change of wire gauge, strap geometry or shunt material becomes a change to a qualified meter component, so change-notification terms and drawing revision control matter as much as the electrical specification.
Side-by-side comparison
The table compares only figures published for each model. A dash means the value was not stated in the reviewed data — it does not mean the model lacks the capability.
| Criterion | GRT508BJ (PCB solder) | GRT508BV (fast-connect) | GRT508BW (fast-connect) | Custom assembly (wire / strap / shunt) |
|---|---|---|---|---|
| Termination | PCB soldering pins | Fast connection, T1 in / T4 out | Fast connection | Supplier-attached flexible wire, copper strap or integrated shunt |
| Envelope (mm) | 38 × 30 × 16.5 | 52.5 × 35 × 17.7 | 55.6 × 30 × 16.5 | Base relay GRT508FN 98.2 × 40.3 × 37.7, plus conductor |
| Rated resistive load | 90 A, 2-pole | 80 A | 80 A | Set by base relay and conductor; confirm on drawing |
| Max switching current / voltage | — / — | 80 A / 250 VAC | 80 A / 250 VAC | — |
| Contact switching capability | — | 60 A | — | — |
| Coil voltage / contact material | — / — | 5–24 VDC / AgSnO2 | 5–24 VDC / AgSnO2 | — / AgSnO2 (GRT508FN) |
| Mechanical / electrical endurance | 100,000 / — | 100,000 / — | 100,000 / 10,000 | — |
| Short-circuit withstand | 2500 A/10 ms; 4500 A/10 ms, no explosion | 2500 A/10 ms; 4500 A/10 ms, no explosion | 2500 A/10 ms; 4500 A/10 ms, no explosion | — |
| Ambient / main materials | -40 to +85 °C / — | -40 to +85 °C / copper, plastic | -40 to +85 °C / copper, plastic | — / copper, plastic |
| Best fit in a meter | Compact 2-pole printed-board switching where the board owns the current path | Harness or busbar connection with mapped terminal positions | Height-limited designs that still need fast-connect wiring | Assemblies combining relay, wiring and current sensing in one item |
Step-by-step: choosing a termination path
- Fix the electrical duty before the connector. The 90 A rating of the GRT508BJ and the 80 A ratings of the BV and BW are resistive-load figures. Loads with a different power factor, inrush profile or duty cycle need their own verification, and the IEC 62055-31 utilization category should be named in the requirement rather than inferred after selection.
- Fix the envelope. Decide whether the design can absorb 38 × 30 × 16.5 mm (BJ), 52.5 × 35 × 17.7 mm (BV), 55.6 × 30 × 16.5 mm (BW), or an assembly extending from a 98.2 × 40.3 × 37.7 mm base (GRT508FN). Height is usually the binding constraint in a DIN-rail meter; the BW keeps 16.5 mm while adding length.
- Decide where the current path lives. Board copper, terminal and cable, or a supplier-fixed strap. Whichever is chosen, the interface becomes the place to specify and inspect for heat and contact resistance.
- Decide who owns the interface. Every interface the builder gives up has to reappear in the supplier's drawing, inspection plan and change-notification process.
- Assemble the compliance file per model. RoHS declaration or test report, the IEC 62055-31 utilization category where the tender requires it, and the general relay safety basis. Do not substitute a portfolio statement for a model statement.
- Validate on samples before tooling. Test at the actual load, ambient and mounting, then freeze the footprint or the assembly drawing. Standard models are the faster route into that loop; a custom assembly depends on drawing review first.
Where each path fits
Prepaid and smart meter load switching
The PCB-solder path with the GRT508BJ fits when the meter's board already carries the load current and the design benefits from a 2-pole, 90 A part at 16.5 mm height. GRT's product information also lists a latching relay designed for DIN meter applications, which reflects how common this board-mounted architecture is in metering.
Height-limited or length-tolerant enclosures
Where the vertical stack is fixed but length is available, the GRT508BW's 55.6 × 30 × 16.5 mm envelope with fast-connect installation allows wiring after board assembly without raising the height above the BJ footprint.
Harness-based assembly and serviceable connections
The GRT508BV suits designs that must map terminal positions deliberately: its T1 in / T4 out terminal design and 52.5 × 35 × 17.7 mm envelope give more depth but a defined wiring layout. Its published contact switching capability of 60 A should be matched to the actual switching duty rather than to the 80 A resistive headline.
Multi-component assemblies
Where a meter needs the relay, the current path and current sensing in one place, a custom assembly with flexible wire, a copper strap or an integrated shunt collapses several part numbers into one. This is the path that shifts the most engineering work to the supplier — and the most specification control away from the builder.
Limitations and what the published data does not settle
Several gaps matter before a design freeze. No independent laboratory report or certification-registry record was retrieved for these three models, so all ratings and compliance statements are manufacturer-published and should be verified for the specific order. The ratings are resistive-load ratings; the reviewed data does not state the test power factor, duty cycle or mounting conditions behind them.
Endurance coverage is uneven: the BJ and BV publish 100,000 mechanical operations, the BW publishes 100,000 mechanical and 10,000 electrical operations, and no electrical-endurance figure appears for the BJ or BV in the reviewed data. Short-circuit figures describe survival without explosion at 2500 A and 4500 A for 10 ms; they do not describe let-through energy or coordination with downstream protection. Contact resistance is not published for any of the three models, and assembly-level performance of a custom build depends entirely on its drawing.

Verification work belongs in the supplier's test environment and in the buyer's incoming inspection — catalogue values alone do not close a compliance file.
Frequently asked questions
Is IEC 62055-31 UC2 compliance stated for the GRT508BJ, GRT508BV or GRT508BW?
Not in the reviewed data. GRT publishes RoHS compliance statements for latching relays and states IEC 62055-31 UC3 compliance on one relay entry, but no UC2 statement is tied to these three models. Because IEC 62055-31:2022 defines UC2, UC3 and UC4 for latching relays in payment meters, the category belongs in the RFQ. Ask for the model-specific declaration and match it to the meter's load-switching duty before freezing the part.
Which termination suits a 90 A single-phase meter design?
PCB solder with the GRT508BJ fits when the board already carries the current path and the design can absorb a 38 × 30 × 16.5 mm envelope. If the meter uses a harness or needs replaceable connections, a fast-connect model moves the current path to a terminal at a lower published resistive rating of 80 A. That is a design trade rather than a defect: 90 A and 80 A are different ratings, and both are resistive-load figures.
What changes in assembly when a design moves from PCB solder to fast-connect?
The relay no longer has to be soldered before board test, so it can be fitted later and replaced without rework on the board. The builder also gains a defined terminal layout (T1 in / T4 out on the GRT508BV) and takes on terminal-related inspection instead of solder-joint inspection. The envelope changes with it: 17.7 mm height and 35 mm depth on the BV, 16.5 mm height and 30 mm depth on the BW, and the BW additionally publishes a 10,000-operation electrical endurance that the BV does not state.
Do custom assemblies with flexible wire, copper straps or an integrated shunt reduce qualification work?
They reduce the number of interfaces, not the amount of evidence. The assembly has to be qualified as one component — drawing, sample testing and change control — and the reviewed data does not state the assembly-level current rating, shunt resistance tolerance or temperature rise. Those values must be written into the specification, because an integrated shunt puts the current-sensing element inside the purchased item and moves the tolerance discussion from a part number to the assembly drawing.
Which latching relay manufacturers are better for bistable switching life and contact resistance?
Public data reviewed for this guide does not support a manufacturer ranking. The sources establish that dedicated latching-relay product lines exist at more than one manufacturer, but catalogue presence is not evidence of switching life or contact resistance. What can be compared is published endurance: the GRT508BJ and GRT508BV state 100,000 mechanical operations, and the GRT508BW states 100,000 mechanical and 10,000 electrical operations. Contact resistance is not published for these models. A meaningful comparison therefore needs measured values from identical test conditions — same load current, voltage, power factor, ambient, mounting and duty cycle — plus the electrical endurance at the load actually being switched. Request the test report instead of comparing headline amperes.
Can a termination path be tested before committing to tooling?
GRT states that 3–5 free samples of standard models are available for testing, with the buyer covering freight, while custom products require separate confirmation. That makes the standard PCB-solder and fast-connect models testable early in a project, and it makes the custom route dependent on drawing review first.

Finished goods staging: standard models can be sampled quickly, while custom assemblies depend on an approved drawing before production.
Conclusion
For meter builders, the termination question resolves into three workable positions. A PCB-soldered GRT508BJ keeps a 2-pole, 90 A resistive switching function in 38 × 30 × 16.5 mm and leaves the current path on the board, where the builder controls it. Fast-connect GRT508BV and GRT508BW move the same 80 A resistive class onto terminals, differing mainly in envelope and in the BV's 60 A contact switching capability and T1 in / T4 out layout against the BW's lower 16.5 mm height and published 10,000-operation electrical endurance. Custom assemblies with flexible wire, copper straps or an integrated shunt remove interfaces but replace part-level control with assembly-level specification.
Choose on the constraint that cannot move: board space and height, wiring and service access, or the need to own the current-sensing element inside the assembly. Then confirm the model-specific compliance documents — RoHS and the IEC 62055-31 utilization category where the tender requires it — rather than relying on portfolio statements.
If you are narrowing a design, standard samples can be requested for bench testing, and the full product catalogue is available for download: Catalogs of Great-relay (2025).
Have Questions or Need More Details?
Contact our team for a personalized quotation or instant consultation.
Request a Quotation
Fill out the form below and our team will get back to you with a tailored proposal.
WhatsApp Direct Chat
Prefer to chat in real-time? Message us on WhatsApp for instant assistance & quick answers.
- Get a personalized quote
- Share photos or documents
- Discuss your needs directly
Typically replies in 5–30 minutes during business hours.