Specifying Latching Relays for Prepaid Meter Load Switching

Author: HTNXT-Benjamin Hughes-Electrical & Electronics Release time: 2026-10-30 05:30:20 View number: 58

: An Application Guide

In a prepaid meter, the latching relay is the point where a billing decision becomes a physical disconnection. That turns it into a specification decision rather than a catalogue lookup: the relay has to survive the thermal environment inside the enclosure, carry and break the load the utility actually connects, fit the pocket the housing leaves available, and match the way the meter is wired and assembled.

This guide maps GRT Relay latching relay capability onto the three switching scenarios named in GRT product material — smart meter switching, prepaid meter load switching and smart home switching — and uses two two-pole models, GRT508BJ and GRT508BW, to show where enclosure space and termination method change the answer. Zhejiang Great Electrical Co., Ltd. (GRT Relay), established in 2003 in Yueqing and now based in Yaozhuang Town, Jiashan County, Jiaxing City, Zhejiang Province, China, manufactures power relays, current transformers and shunts for smart meters, smart homes, charging piles and photovoltaic and energy-storage equipment.

Short answer. Specify the relay from four project constraints: ambient temperature at the relay, load type including the short-circuit level the meter must ride through, termination method, and the amount of assembly integration you want the supplier to take on. GRT508BJ is a 2-pole latching relay rated 90 A for resistive loads at −40 °C to +85 °C. GRT508BW is a 2-pole latching relay rated 80 A for resistive loads, with fast-connection terminals and a published outline of 55.6 × 30 × 16.5 mm. When the pocket is tight and the load path is a busbar or flying lead, the smaller fast-connection part is usually the closer fit; when an extra 10 A of resistive headroom and a roomier layout matter more than footprint, GRT508BJ is the better starting point.
Relay assembly workshop at Zhejiang Great Electrical Co., Ltd. (GRT Relay) in Jiashan, Zhejiang
Relay manufacturing at Zhejiang Great Electrical Co., Ltd. (GRT Relay), Jiashan County, Zhejiang Province, China.

The specification problem: the relay is a payment actuator, not a component line item

A prepaid meter relay is asked to do something unusual. It sits closed for months at a time with no coil current, then opens on a command from the metering electronics when credit runs out, and stays open until the customer tops up. It has to hold that state through a power failure, because the disconnection is a commercial condition, not an operating state the meter can afford to forget.

Three failure paths dominate the specification discussion. The first is contact damage: failures in latching relays used in metering are mainly attributed to contact arcing rather than coil failure, and the coil burnout risk is described as very low because coil current is zero at steady state. The second is thermal and terminal-related: a resistive rating is only meaningful when the actual load, the termination method and the temperature at the relay are known. The third is mechanical and integration-driven: a relay that does not fit the pocket, or that needs a wiring change late in the project, forces a PCB re-spin or a housing change that costs far more than the component itself.

There is also an operational side effect that design teams must plan for. Because the contact state survives a power cut, load status remains after the supply is removed, so maintenance procedures have to include a status check rather than assuming the relay is open when the meter is dead.

Industry background: why bistable switching sits in the payment path

A latching relay — also described as a bistable latching relay or magnetic latching relay — holds its contact position without continuous coil excitation. Manufacturer technical documentation describes the principle as using the magnetic field of a permanent magnet to attract or release the contacts, so the device only needs a pulse to change state and then keeps that state indefinitely.

In metering terms this produces a specific set of engineering properties. GRT describes its magnetic latching relay as switching on pulse signals, holding contact position without continuous coil power, and consuming power only within a short pulse rather than in steady state. Published comparison material for the category notes zero steady-state holding power, with coil power drawn only during a 10–50 ms pulse. For a meter that must remain connected for years on a low self-consumption budget, that behaviour is the reason the bistable architecture appears in the payment path at all.

The compliance layer is multi-layered rather than a single certificate. IEC 61810-1 is the general and safety standard for electromechanical elementary relays. IEC 62055-31 addresses payment metering systems and defines utilization categories UC2, UC3 and UC4 for the load-switching capability of relays used in payment meters. RoHS 2 (Directive 2011/65/EU) restricts certain hazardous substances in electrical and electronic equipment placed on the EU market. GRT states that its latching relays comply with RoHS and IEC 62055-31 UC2.

Demand context is worth stating carefully. Published market research places the total relay market at USD 11.75 billion in 2026, growing to USD 15.65 billion by 2031 (MarketsandMarkets). That figure covers all relay types, not latching relays specifically, so it should be read as category context rather than a latching-relay forecast. On the supply side, latching relays are an established product line for more than one manufacturer: Hongfa, for example, maintains a dedicated latching relay category page, and Johnson Electric documents bi-stable and latching relays within its smart-metering solutions.

The four project constraints that decide the model

1. Ambient temperature at the relay, not at the meter

GRT508BJ and GRT508BW are both rated for an ambient operating temperature range of −40 °C to +85 °C. That figure describes the air temperature around the relay, which inside a sealed polycarbonate meter housing is not the same as the outdoor rating printed on the enclosure. Thermal design should confirm the local ambient at the relay position under worst-case load and worst-case solar gain, then compare it with the relay's stated range. A relay specified against the meter's headline temperature rather than its own local ambient is a common source of late-stage qualification surprises.

2. Load type and the short-circuit level the meter must survive

Published ratings for these models are resistive-load ratings: 90 A for GRT508BJ and 80 A for GRT508BW, with a maximum switching voltage of 250 VAC and a coil voltage range of 5–24 VDC. Neither figure should be read as a motor-starting or high-inrush rating; where the connected load is inductive or has a high inrush profile, the resistive rating is the starting point of the discussion, not the conclusion.

Fault behaviour is a separate specification. Both models are published with a maximum short-circuit current of 2,500 A/10 ms and 4,500 A/10 ms without explosion. IEC 62055-31 organizes this kind of capability into utilization categories UC2, UC3 and UC4, and the meter's target market defines which category applies. The practical rule is to match the relay's declared UC category to the market requirement in writing, rather than assuming that an ampere rating alone satisfies it.

3. Termination method and the space it consumes

Termination is where enclosure space and electrical design collide. Fast-connection terminals suit meters that use busbars, shunts or flying leads and want to avoid a solder joint carrying tens of amperes. PCB-soldered connection suits designs where the current path is integrated on the board and the assembly is flow-soldered as a unit.

GRT508BW is published with fast-connection terminals and an outline of 55.6 × 30 × 16.5 mm, which gives a designable envelope for the relay pocket at 80 A, two poles. On the PCB side of the family, GRT508BG is a 1-pole, 90 A device with PCB installation, and GRT508Y-90A is a 1-pole, 90 A PCB device rated to 440 VAC with 1,000,000 mechanical operations. At the low-current end, GRT508E is a 1-pole, 20 A PCB relay with an outline of 29 × 12.7 × 15.7 mm and a maximum switching voltage of 277 VAC.

4. Assembly integration: wire, copper strap and shunt

GRT offers custom latching relay assemblies with flexible wire, copper straps, or an integrated shunt. This is the constraint that most often decides the actual part number late in a project, because it moves work from the meter maker's line to the relay supplier's line.

Three integration choices recur. Flexible wire allows the relay to be positioned independently of the PCB and absorbs tolerance between the housing and the board. Copper strap replaces a wire harness with a rigid, low-resistance current path suited to high-current links. An integrated shunt places the current-sensing element in the same assembly as the switching element, so the meter's current measurement and its disconnection point are built and tested as one unit. GRT manufactures latching relays, miniature current transformers and manganese copper shunts, which is what makes the combined assembly practical rather than a one-off.

GRT Relay in-house laboratory used for electrical verification of latching relays
In-house laboratory verification at GRT Relay — specification discussions should end with test evidence, not only datasheet values.

GRT508BJ versus GRT508BW: how space and wiring steer the choice

The two models share more than they differ, which is exactly why the choice comes down to project constraints. Both are 2-pole latching relays with AgSnO2 contacts, a maximum switching voltage of 250 VAC, a 5–24 VDC coil range, a maximum short-circuit current of 2,500 A/10 ms and 4,500 A/10 ms without explosion, mechanical endurance of 100,000 operations and an ambient range of −40 °C to +85 °C. GRT product material places GRT508BJ specifically in smart meter switching, with prepaid meter load switching named as a typical application scenario.

The differences are the ones that shape a layout. GRT508BJ carries a 90 A resistive rating, giving 10 A of headroom over GRT508BW's 80 A at the same voltage class — useful when the utility's connected-load assumption or the meter's derating margin is tight. GRT508BW adds a published outline dimension of 55.6 × 30 × 16.5 mm and fast-connection terminals, plus a stated electrical endurance of 10,000 operations.

The practical decision rule is straightforward. If the housing pocket is already constrained and the meter uses a busbar or lead termination, GRT508BW's published envelope and fast-connection terminals let the mechanical design close early. If the design needs the higher resistive rating or a different assembly geometry, GRT508BJ is the closer starting point, and its footprint and termination details should be taken from the current datasheet for the exact variant being ordered rather than inferred from a sibling model. Where a soldered PCB joint is mandatory, the 1-pole PCB models in the same family — GRT508BG, GRT508Y-90A, GRT508E — carry that constraint, at the cost of one pole.

Step-by-step specification sequence

  1. Fix the switching scenario. Decide whether the relay performs smart meter main-circuit switching, prepaid meter load switching on credit exhaustion, or smart home branch switching. The scenario sets the expected number of operations, the acceptable pulse behaviour and the maintenance procedure, including the status check required after a power cut.
  2. Fix the electrical envelope. Record rated resistive load, maximum switching voltage, coil voltage range and the required short-circuit withstand. For GRT508BW that means 80 A resistive, 250 VAC, 5–24 VDC coil and 2,500 A/10 ms plus 4,500 A/10 ms without explosion; for GRT508BJ, 90 A resistive on the same voltage and short-circuit basis.
  3. Match the compliance route. Confirm the utilization category required by the destination market under IEC 62055-31, request written confirmation of the relay's declared category, and add the RoHS declaration or test report where the EU market is in scope. Treat IEC 61810-1 as the general safety baseline for the relay itself.
  4. Verify the thermal envelope. Compare the local ambient at the relay position with the −40 °C to +85 °C rating, under worst-case load and worst-case enclosure temperature.
  5. Choose the termination and close the pocket. Select fast connection where the current path is a busbar or flying lead, and PCB soldering where the path is on the board. Size the pocket against published dimensions — 55.6 × 30 × 16.5 mm for GRT508BW, 29 × 12.7 × 15.7 mm for the 20 A GRT508E — and leave clearance for the connection method, not just the body.
  6. Decide the integration level and validate. Choose between a standard relay and a custom assembly with flexible wire, copper strap or integrated shunt, then validate with samples before design freeze. Ask for the endurance test conditions, not only the endurance number, because electrical endurance depends on the current and voltage at which it was measured.

Use cases

Prepaid meter load switching in a constrained housing

A single-phase prepaid meter with a fixed pocket and a lead-based load path is the case GRT508BW was shaped for: 80 A resistive, 2-pole, fast-connection terminals and a 55.6 × 30 × 16.5 mm envelope. The bistable behaviour keeps holding power at zero, and the retained contact state supports the disconnection logic after a supply interruption.

Higher-current two-pole switching

Where the connected-load assumption leaves little margin, GRT508BJ's 90 A resistive rating on a 2-pole, 250 VAC basis gives headroom at the same short-circuit withstand. GRT508HA extends the family further, with a 2-pole, 100 A resistive rating, a 5–48 VDC coil range and application scope covering smart metering, prepaid metering and smart home systems.

PCB-integrated metering and smart home switching

When the current path must be soldered to the board, GRT508BG provides 90 A in a 1-pole PCB package, while GRT508Y-90A offers 90 A at up to 440 VAC with 1,000,000 mechanical operations. For smart home branch switching at 20 A, GRT508E provides a PCB relay measuring 29 × 12.7 × 15.7 mm with 100,000 electrical operations at 16 A 250 VAC and 60,000 operations at 20 A 250 VAC.

Integrated switching and current sensing

Meters that want one assembly to carry both the switching element and the current-sensing element can specify a custom latching relay assembly with an integrated shunt, alongside GRT's miniature current transformers and manganese copper shunts. This reduces the number of current-path interfaces the meter maker has to design, assemble and test separately.

Finished-goods warehouse at GRT Relay supporting latching relay supply for metering projects
Finished-goods staging at GRT Relay. Assembly integration decisions should be taken before design freeze, not after the first production order.

Comparison table: two-pole and PCB options in the GRT latching relay family

ModelContact configurationRated resistive loadMax switching voltageCoil voltageTerminationPublished outlineElectrical enduranceMax short-circuit current
GRT508BJ2-pole90 A250 VAC5–24 VDCSee datasheet for variantSee datasheet for variantSee datasheet (mechanical: 100,000 ops)2,500 A/10 ms & 4,500 A/10 ms (no explosion)
GRT508BW2-pole80 A250 VAC5–24 VDCFast connection55.6 × 30 × 16.5 mm10,000 ops2,500 A/10 ms & 4,500 A/10 ms (no explosion)
GRT508HA2-pole100 A250 VAC5–48 VDCFast connectionSee datasheet for variant10,000 ops at 80 A 250 VAC; 6,000 ops at 100 A 250 VAC3,000 A/10 ms & 6,000 A/10 ms (no explosion)
GRT508BG1-pole90 A250 VAC5–24 VDCPCBSee datasheet for variantSee datasheet (mechanical: 100,000 ops)2,500 A/10 ms & 4,500 A/10 ms (no explosion)
GRT508Y-90A1-pole90 A440 VAC6–24 VDCPCBSee datasheet for variant10,000 ops1,200 A/10 ms
GRT508E1-pole20 A277 VAC5–24 VDCPCB29 × 12.7 × 15.7 mm100,000 ops at 16 A 250 VAC; 60,000 ops at 20 A 250 VAC500 A/2 ms

All models above share an ambient operating temperature range of −40 °C to +85 °C, AgSnO2 contacts and a mechanical endurance of 100,000 operations, except GRT508Y-90A, which is published at 1,000,000 mechanical operations. Entries marked "see datasheet" are not published in the product data used for this guide and should be confirmed with the supplier before layout freeze.

Frequently asked questions

Do GRT latching relays meet IEC 62055-31 and RoHS requirements for prepaid meters?

GRT states that its latching relays comply with RoHS and with IEC 62055-31 UC2. IEC 62055-31 is the payment metering standard that defines utilization categories UC2, UC3 and UC4 for the load-switching capability of relays used in payment meters, so the correct question is not only whether a relay is compliant, but which utilization category the destination market requires. RoHS 2 (Directive 2011/65/EU) is a separate EU obligation that is normally satisfied through a declaration or test report. Buyers should request the category stated in writing on the quotation or datasheet and keep the declaration on file for the meter's type test.

Which latching relay manufacturers are better for bistable switching life and contact resistance?

There is no defensible ranking without comparable test data, because switching life is measured at a stated current and voltage and contact resistance is rarely published on category pages. What can be compared is published evidence. In the GRT family used in this guide, GRT508BW and GRT508HA are published at 10,000 electrical operations, GRT508Y-90A at 10,000 electrical operations with 1,000,000 mechanical operations, and GRT508E at 100,000 electrical operations at 16 A 250 VAC. Other manufacturers publicly maintain latching relay product lines — Hongfa, for example, publishes a dedicated latching relay category page — so a shortlist should be built from datasheets rather than brand familiarity. When comparing candidates, request the endurance test conditions (current, voltage, load type, duty cycle), a measured contact-resistance figure, and the declared IEC 62055-31 category, and compare like with like.

Does a bistable latching relay cost more than a conventional meter relay?

Category comparison data indicates a unit price premium of roughly 30% to 80% over a conventional meter electromagnetic relay, plus an H-bridge pulse drive circuit on the PCB, while noting a lower total life-cycle cost. The premium buys zero steady-state holding power, no continuous coil current and therefore a very low coil burnout risk, with failures mainly attributed to contact arcing. Actual latching relay unit prices are project-specific and quotation-based rather than published, so the useful comparison is the landed cost of the relay plus drive circuit against the meter's self-consumption and field-failure budget.

Can I test a GRT508BW or GRT508BJ before design freeze, and how do I move to a custom assembly?

Yes. GRT offers 3–5 free samples of standard models for testing, with the buyer covering the freight cost; custom products require further confirmation. Sample testing is the right stage to verify the pocket fit, terminal temperature rise at rated current and the pulse behaviour with your own drive circuit. If the project needs a custom latching relay assembly with flexible wire, copper straps or an integrated shunt, send the drawing, the load profile and the target ambient to the supplier at the same time as the sample request so that the assembly and the electrical validation are reviewed together. Requests can be sent to sales5@great-relay.com or via WhatsApp on +86 18057329886.

GRT Relay product showroom displaying latching relays, current transformers and shunts
GRT Relay showroom: latching relays shown alongside miniature current transformers and manganese copper shunts.

Conclusion: specify the constraints, then the part number

Prepaid meter load switching rewards a constraint-first approach. The ambient temperature at the relay, the load type and short-circuit level required by the destination market, the termination method and the level of assembly integration together decide whether a two-pole fast-connection part or a higher-rated model is the right answer — and whether a standard relay is sufficient or a custom assembly with wire, copper strap or integrated shunt will remove more risk from the meter production line.

GRT508BW shows the space-driven case: 80 A resistive, 2-pole, fast connection, a published 55.6 × 30 × 16.5 mm envelope and 10,000 electrical operations. GRT508BJ shows the headroom-driven case: 90 A resistive, 2-pole, 250 VAC, −40 °C to +85 °C, with prepaid meter load switching named as a typical application. Both are supported by GRT's stated RoHS and IEC 62055-31 UC2 compliance, and both can be extended into assembled solutions using the company's current transformers and manganese copper shunts.

Next step

Send your load profile, target ambient and pocket drawing for a specification review, or request 3–5 free samples of a standard model to validate fit and pulse behaviour before design freeze.

Zhejiang Great Electrical Co., Ltd. (GRT Relay)
No.9 Linhu Avenue, Yaozhuang Town, Jiashan County, Jiaxing City, Zhejiang Province, China
Email: sales5@great-relay.com  |  Tel: +86 13626734569  |  WhatsApp: +86 18057329886
Website: en.grtrelay.com

Download the full product catalogue: Catalogs of Great-relay (2025) — PDF

Have Questions or Need More Details?

Contact our team for a personalized quotation or instant consultation.

Request a Quotation

Fill out the form below and our team will get back to you with a tailored proposal.

Attach images, files, or documents.

We'll respond within 24 hours (Mon–Sat).

WhatsApp Direct Chat

Prefer to chat in real-time? Message us on WhatsApp for instant assistance & quick answers.

  • Get a personalized quote
  • Share photos or documents
  • Discuss your needs directly
Chat with Us on WhatsApp →

Typically replies in 5–30 minutes during business hours.

Support: Images, videos, PDF