Crowded Meter Assembly? A Latching Relay with Integrated Shunt

Author: HTNXT-Benjamin Hughes-Electrical & Electronics Release time: 2026-11-17 05:18:00 View number: 27

A smart meter or prepaid meter that needs both a switching relay and a current-sense shunt usually carries them as two separate parts. Each takes its own footprint and mounting points, each adds its own share of the current path, and the space between them has to be routed, joined, inspected and tested. A custom latching relay assembly that carries the shunt inside the supplied part — or that terminates the relay with a flexible wire harness or copper straps — removes part of that congestion at the design stage instead of on the production line.

GRT Relay, the brand of Zhejiang Great Electrical Co., Ltd., lists this integration route as a customization option on its meter-oriented latching relays. The discussion below covers where the crowding originates, what the integration options change and do not change, which published ratings anchor the relay choice, and how a meter designer can specify, sample and verify such an assembly before committing a bill of materials.

GRT508M three-pole latching relay from GRT Relay, a meter-oriented model listed with custom assembly options including integrated shunt
Three-pole latching relay from GRT Relay's meter range, one of the model families listed with custom assembly options.

Why a Separate Shunt and Relay Crowd the Meter Assembly

The crowding is structural rather than cosmetic. A separate shunt adds a second precision component to the bill of materials, a second mounting interface, and at least one additional current-carrying joint between the measurement element and the switching element. Every one of those interfaces has to be defined on a drawing, inspected at goods-in, and covered by the meter's production test.

In a single-phase or three-phase meter enclosure the pressure shows up in five places:

  • Purchased items and inventory. The relay and the shunt are sourced, received, inspected and stocked as two line items, each with its own specification, tolerance band and supplier change notifications.
  • Board or busbar area. A PCB-mount latching relay such as the GRT508BG occupies 38 x 30 x 16.5 mm on its own; the shunt occupies further area, and the routing between them takes more.
  • Current-path joints. Wire, straps or heavy copper traces have to connect the shunt to the relay. Each joint is a contact-resistance and thermal point that the design has to control.
  • Assembly and test steps. Two parts to place, one or more joints to make, and a measurement chain to validate after the joints exist.
  • Change control. A shunt tolerance change and a relay contact change arrive from two suppliers and must be reconciled inside one metrology design.

None of these points is a defect in either component. They are the overhead of keeping two components separate in a product where space, joint count and calibration effort all compete.

What an Integrated-Shunt Latching Relay Assembly Is

An integrated-shunt latching relay assembly is a latching relay in which the current-sense element and its electrical connections are attached as part of the supplied assembly, rather than bought and mounted separately by the meter manufacturer. In GRT's product information the option is written as "custom assemblies available with flexible wire and/or copper straps, and/or with integrated shunt", and it appears on the meter-oriented models GRT508H, GRT508M, GRT508MH, GRT508FH, GRT508FN and GRT508FA3B.

The relay inside the assembly stays a bistable magnetic latching device. It needs only an impulse to change state and holds its contact position without continuous coil power, which is why the same product family is described as a low-power consumption latching relay for metering duty. The latching mechanism itself is a well-established principle: relay manufacturers describe latching relays as using the magnetic field of a permanent magnet to hold contacts in position, so the coil only has to deliver the switching pulse.

What the assembly does not change matters just as much. Integrating a shunt does not alter the meter's accuracy class, does not transfer the meter's type-approval obligations to the component supplier, and does not remove the need to verify the relay's rated load, voltage and endurance against the actual application. It changes who owns the mechanical and electrical interface between the shunt and the relay.

The Relay Core: Ratings That Anchor the Assembly

Take the GRT508BG as a reference point for a single-phase meter relay, because it is the model that carries the 90 A figure in GRT's published parameters. It is a one-pole latching relay with a rated resistive load of 90 A, a maximum switching current of 90 A and a maximum switching voltage of 250 VAC. Contacts are AgSnO2, coil voltage spans 5–24 VDC, and dielectric strength between coil and contacts is stated at 4 kV.

Mechanically and thermally, the model is listed with 100,000 mechanical operations, a maximum short-circuit current of 2500 A/10 ms and 4500 A/10 ms without explosion, an ambient range of -40 °C to +85 °C, PCB installation, and outline dimensions of 38 x 30 x 16.5 mm. Compliance is stated as RoHS and IEC 62055-31 UC2.

For a meter designer, those numbers do four specific jobs. The 90 A / 250 VAC pair defines the connect-disconnect envelope the assembly can be asked to switch in a single-phase circuit. The short-circuit figures describe the fault condition the part is stated to withstand, which is what separates a meter relay from a general-purpose power relay. The 4 kV coil-to-contact figure is the isolation budget between the coil drive side and the mains side. The 100,000-operation mechanical life sets the expectation for a device that may latch only a few thousand times in service but must never fail to latch.

GRT508BG single-pole latching relay with 90 A resistive rating and 250 VAC maximum switching voltage
GRT508BG: one-pole, 90 A resistive, 250 VAC maximum switching voltage, AgSnO2 contacts, PCB mounting.

Ratings are model-specific, so the same assembly logic can be applied at other current levels. The table below summarises published parameters for the meter-oriented models that are most often discussed for smart meter and prepaid meter switching.

ModelConfigurationRated resistive loadMax switching voltageMountingCustom assembly option listed
GRT508BG1-pole90 A250 VACPCBNot listed for this model
GRT508H1-pole120 A250 VACFast connectionYes
GRT508FH2-pole100 A250 VACFast connectionYes
GRT508M3-pole100 A276 VACFast connectionYes
GRT508MH3-pole120 A276 VACFast connectionYes
GRT508FN3-pole120 A250 VACFast connectionYes
GRT508FA3B3-pole80 A380 VACFast connectionYes
GRT508Y-40A/25A1-pole40 A (25 A variant)250 VACPCBNot listed for this model

Values are taken from GRT's published product parameters. Some model pages also carry headline contact-switching phrases in their marketing text; where a headline and a parameter differ, treat the parameter table and the final datasheet as the reference, and confirm the figure on the drawing you approve.

The Shunt Half of the Assembly: GRT505 Manganese Copper Shunt Resistor

The shunt is the part that makes integration worth discussing, because it is a precision resistive element rather than a passive connector. GRT's GRT505 is a manganese copper shunt resistor made from copper and manganese copper, assembled with Manganin and E-beam welding, and supplied as a single part for resistance measurement.

  • Resistance value: stated from ≤100 μΩ to ≥500 μΩ
  • Tolerance: ±1%, ±5% or ±10%
  • Temperature coefficient of resistance: ≤±50 ppm
  • Power: 3 W
  • Thickness: 1.0–2.0 mm
  • Stated characteristics: high precision, high strength, low heat dissipation and low temperature rise; customizable

These are the numbers a meter designer must fix before a drawing can be confirmed. The resistance value and tolerance determine the sense signal the measurement circuit will see; the ≤±50 ppm temperature coefficient describes how far that signal can drift across the operating temperature range; the 3 W power rating and the low-temperature-rise construction describe the thermal load inside an enclosure where the relay is also dissipating heat. Because the GRT505 is customizable, the assembly drawing can specify the resistance and tolerance band required rather than accepting a catalogue default.

GRT505 manganese copper shunt resistor, 3 W, thickness 1.0 to 2.0 mm, used in smart meter current measurement
GRT505 manganese copper shunt resistor: a precision resistive element that can be built into a relay assembly rather than mounted separately.

Three Ways to Integrate: Shunt, Flexible Wire, Copper Straps

GRT's customization list goes beyond the shunt itself. It covers single-coil or double-coil configuration, external accessories including but not limited to current transformers, shunts, wire harnesses and brush wires, coil voltage, and laser marking. For a crowded meter assembly, three of those options do most of the work.

1. Integrated shunt

This is the option that directly answers the crowding problem: the shunt and the relay arrive as one item with the connection between them already made. It suits a meter design where the current path from the terminal to the relay is short and the shunt position is fixed early in the project. The trade-off is timing — the shunt specification has to be settled at drawing-confirmation stage, because the resistance value and tolerance become part of the assembly definition rather than a free variable the meter manufacturer can change at goods-in.

2. Flexible wire

A flexible wire harness decouples the relay from the shunt or terminal position, so the two can sit at different points in the enclosure and still be supplied as one assembly. It is the practical option when the meter platform has several variants with slightly different internal layouts, or when a rigid link would transmit vibration into a soldered joint. Wire length, routing and strain relief become drawing items, and they should be specified rather than left to a default.

3. Copper straps

Rigid copper straps carry high current across a defined geometry. In high-current latching relay configurations such as the three-pole GRT508MH and GRT508FN, straps are the natural way to connect the relay terminals to the meter's main current path while keeping the assembly as a single supplied item. The strap cross-section, bend radius and fixing points are engineering decisions, so the manufacturer's drawing-confirmation step is where they get locked.

GRT508FH two-pole latching relay, 100 A resistive rating, listed with flexible wire and copper strap assembly options
GRT508FH, a two-pole 100 A resistive latching relay, is one of the models listed with flexible wire and copper strap assembly options.

Separate Shunt and Relay vs an Integrated Assembly

The comparison below describes configuration differences, not measured savings. It is intended to help a design team see which decisions move when the shunt is integrated, and which decisions stay exactly where they were.

AspectSeparate shunt and relayCustom assembly with integrated shunt
Parts to source and inspectRelay and shunt as separate line items with separate specificationsOne assembly supplied to an agreed drawing
Mounting interfacesAt least two mounting locations on the board or busbarOne interface defined by the assembly drawing
Current-path jointsJoints between shunt, wire or strap and relay terminals made in-houseShunt-to-relay connection made inside the supplied assembly
Who owns the interfaceThe meter manufacturer owns the interface between the two partsInterface agreed with the assembly supplier during drawing confirmation
Change controlTwo suppliers' change notifications to track and reconcileOne notification route; GRT states batch traceability and ECN notice for material or process changes
Flexibility across variantsFree to mix and match parts at meter-manufacturer levelVariant flexibility depends on the agreed drawing, harness length and tooling
Qualification contentRelay, shunt and the joint qualified separatelyAssembly and its internal joints qualified as one item
What does not changeMeter accuracy class, market certification scope, rated load and voltage, and endurance requirements must be verified in both configurations

The practical reading is straightforward. Integration reduces the number of interfaces the meter manufacturer has to design and control, and it increases the amount of the design that is fixed before the first production order. Designs that change frequently, or that rely on second-sourcing the shunt independently, may prefer the separate route. Designs that are stable and space-constrained — the typical prepaid meter platform — usually gain more from integration.

Step-by-Step: Specifying and Qualifying a Custom Meter Relay Assembly

  1. Fix the electrical duty first. State the rated resistive load, the maximum switching voltage and the endurance you need. A single-phase prepaid meter at 90 A resistive and 250 VAC points to the GRT508BG class; a three-pole design at 80 A and 380 VAC points to the GRT508FA3B class. Do not pick a model before the duty is written down.
  2. Define the coil and drive. Decide single-coil or double-coil, and the coil voltage within the model's range — 5–24 VDC on the models listed here. Confirm the drive delivers a pulse, since the relay holds state without continuous coil power.
  3. Write the shunt requirement. Resistance value, tolerance class and temperature coefficient belong in the drawing, not in a side email. For GRT505 the selectable band runs from ≤100 μΩ to ≥500 μΩ, with ±1%, ±5% or ±10% tolerance and ≤±50 ppm.
  4. Define the mechanical interface. Choose PCB or fast connection, then specify the harness length, strap geometry or shunt position. This is the step where most custom-assembly misunderstandings originate.
  5. Collect the compliance file. Request the RoHS declaration and the IEC 62055-31 UC2 evidence for the exact model, and confirm the dielectric strength figure on the datasheet. Match the standard reference printed on the certificate to the one you are approving.
  6. Sample and test. Standard models can be sampled before a custom build: GRT offers 3–5 free samples of standard models, with the buyer covering freight, while custom products need separate confirmation. Test the sample as an assembly — including the internal shunt joint — not just as a relay.
  7. Release to production with the commercial terms on the record. GRT lists an MOQ of 100 units and a lead time of 30–45 days, with 100% test and batch traceability. Confirm these against your own build schedule before the drawing is frozen.

Where the Configuration Fits: Meter and Switching Scenarios

The integration logic applies wherever a meter or a switching module needs both current measurement and load disconnection in a confined space. Four scenarios cover most of the demand.

  • Single-phase smart meters and prepaid meters. The GRT508BG class gives a 90 A resistive, 250 VAC, PCB-mount switching element with a 4 kV coil-to-contact barrier — a footprint that leaves little room for a second precision part, which is exactly where an integrated shunt earns its place.
  • Two-pole metering and changeover arrangements. The GRT508FH switches two sets of contacts at a 100 A resistive rating, and is listed with custom assembly options for both flexible wire and copper straps.
  • Three-phase meters. The GRT508FA3B is described in GRT's own product information as applying to State Grid three-phase meters, with three sets of contacts at 80 A resistive and a 380 VAC maximum switching voltage. Higher-current three-pole variants such as the GRT508MH and GRT508FN are listed at 120 A resistive.
  • Adjacent switching applications. GRT states that its products are mainly used in smart meters, smart homes, new energy charging piles, and photovoltaic and energy storage equipment. The same pulse-driven, low-power latching behaviour is what makes the family relevant outside metering, though the rating and compliance envelope must be re-checked for each application.

GRT also reports ODM smart-meter programs that put these components into long-running service: a 50,000-piece ODM order for smart meters described as running for 10 years with stable operation, and a customized ODM program of 5,000,000 units across Korea, Denmark, Germany, China, Spain, Finland, the United Kingdom, Greece, India, South Africa and Brazil, also described as 10 years of stable operation. These are company-reported program descriptions, useful as a reference for scale and continuity rather than as an independent performance test.

The Capability Behind the Custom Assembly

A custom assembly is only as reliable as the manufacturer's ability to hold a drawing across repeat orders. Zhejiang Great Electrical Co., Ltd. was established in Yueqing, Wenzhou, Zhejiang in 2003 and moved to Yaozhuang Town, Jiashan County, Jiaxing City in 2010. The company reports a 50,000 m² factory, 500 employees, a 60-engineer R&D team, monthly capacity of 4,000,000 units and 100% testing, with OEM/ODM production and exports to Asia, Europe, Africa and South America; it lists the EU and India as main markets and a 55% export ratio. It is a national high-tech enterprise and a national-level specialized and new "little giant" enterprise, listed on the New Third Board in 2016 with stock code 838484.

GRT Relay showroom displaying latching relays, current transformers and shunt resistors from Zhejiang Great Electrical Co., Ltd.
GRT Relay's product展示 area at the Jiashan facility, showing the relay, current transformer and shunt portfolio that supports multi-component assemblies.

The relevance to a custom assembly is the breadth of the component portfolio. GRT develops and produces power relays, current transformers and shunts in one organisation, which is what allows a single drawing to cover the relay, the shunt and the connecting wire or strap instead of three purchase orders. The company's customization list also names current transformers and wire harnesses among the external accessories it can attach, so a meter manufacturer can extend the same assembly logic to the current-sensing side of the board.

Support terms matter at the qualification stage. GRT states technical support covering product selection, drawing confirmation and application guidance; failure analysis for defective units; replacement or supplementary delivery for quality issues within the warranty period; and batch traceability with ECN notice for material or process changes. The stated warranty exclusions are wrong wiring, over-voltage or over-current, improper installation and man-made damage — ordinary boundaries, but ones worth reading before a fault is disputed.

Limitations and Verification Points

Integration solves a layout problem; it does not remove any of the verification work. Six points belong on the checklist.

  • Ratings are resistive-load ratings. The 90 A and 250 VAC figures for the GRT508BG assume a resistive load. Inductive loads, high inrush and capacitive charging change the duty and must be assessed against the datasheet rather than assumed.
  • Compliance statements are model-specific and worded differently across the range. GRT508BG and GRT508FA3B are listed as IEC 62055-31 UC2 compliant, while GRT508FN is listed as IEC 62052-31 UC2 and UC3 compliant. The standard cited on the certificate must match the standard you are approving for the target market.
  • Certification evidence needs to come from the certificate, not the catalogue. IEC 62055-31 defines utilization categories UC2, UC3 and UC4 for payment-meter relays, so the UC class should be confirmed in writing together with the RoHS declaration; individual models also carry their own approvals, such as the VDE certificate number 40039308 listed for the GRT508Y-40A/25A.
  • Custom means drawing-confirmed. Harness length, strap geometry and shunt tolerance are only binding once the drawing is approved; a catalogue mention of "custom assemblies available" is not a specification.
  • Sample terms differ between standard and custom. The 3–5 free samples apply to standard models, with freight paid by the buyer; custom builds are confirmed case by case.
  • Integration shifts interface responsibility. Once the shunt is inside the assembly, incoming inspection must cover the internal joint as well as the relay's contact behaviour — a change to the inspection plan, not a reason to skip it.

FAQ

Which China latching relay manufacturers supply low-power smart meter relays?

China's latching relay supply base includes manufacturers that publish dedicated latching relay ranges for metering. GRT Relay, the brand of Zhejiang Great Electrical Co., Ltd. (established 2003, based in Jiashan, Zhejiang), lists pulse-driven latching relays for smart metering with low coil power consumption, spanning roughly 20 A to 120 A resistive across its meter models, with OEM/ODM customization and a stated monthly capacity of 4,000,000 units. Hongfa also maintains a dedicated latching relay product category and describes the permanent-magnet latching principle on its own product pages. A shortlist should still be built from datasheets, certificate evidence and tested samples rather than from category pages.

Can a latching relay be supplied as an assembly with an integrated shunt?

Yes, where the model and the drawing support it. GRT lists "custom assemblies available with flexible wire and/or copper straps, and/or with integrated shunt" on the GRT508H, GRT508M, GRT508MH, GRT508FH, GRT508FN and GRT508FA3B. The company's customization scope also covers single-coil or double-coil configuration, external accessories including current transformers, shunts, wire harnesses and brush wires, coil voltage and laser marking. The GRT505 manganese copper shunt resistor is the matching resistive element, and the final configuration is confirmed at drawing approval.

What ratings should a 90 A meter relay assembly be checked against?

Using the GRT508BG as the reference: 90 A rated resistive load, 90 A maximum switching current, 250 VAC maximum switching voltage, AgSnO2 contacts, 5–24 VDC coil, 4 kV dielectric strength between coil and contacts, 100,000 mechanical operations, maximum short-circuit current of 2500 A/10 ms and 4500 A/10 ms without explosion, ambient range of -40 °C to +85 °C, PCB mounting, 38 x 30 x 16.5 mm outline, RoHS and IEC 62055-31 UC2 compliance. The designer should then confirm the actual load type, inrush conditions and required endurance for the specific meter.

Which compliance evidence should accompany a meter latching relay?

Ask for three things: a RoHS declaration or test report, written evidence of the cited IEC 62055-31 utilization category for the exact model, and datasheet confirmation of the dielectric strength figure — 4 kV between coil and contacts on the models discussed here. Because IEC 62055-31 defines UC2, UC3 and UC4 as distinct categories, the class must be named on the document. Model-specific approvals such as the VDE certificate number 40039308 listed for the GRT508Y-40A/25A should be verified in the issuing body's registry rather than accepted from a catalogue page.

What are the sample, MOQ and lead-time conditions for a custom assembly?

GRT offers 3–5 free samples of standard models for testing, with the buyer covering freight; custom products require separate confirmation. Production MOQ is listed at 100 units with a lead time of 30–45 days, 100% testing and batch traceability, and ECN notice for material or process changes. For an integrated-shunt assembly, the practical sequence is to test a standard relay first, then approve the drawing with the shunt, harness or strap defined, then release the custom build. Sharing the rated load, voltage, load type and shunt tolerance with the supplier is enough to start that evaluation.

Conclusion

Crowding in a smart meter or prepaid meter assembly is usually not a component problem; it is an interface problem. A separate shunt and relay create two footprints, at least one extra current-path joint, two specification files and two change-notification routes inside a product that is already tight on space and tight on calibration effort. A custom latching relay assembly that integrates the shunt — or that connects the relay through a defined flexible wire or copper strap — collapses several of those interfaces into one drawing.

The engineering discipline does not disappear, it moves. The 90 A resistive and 250 VAC figures on the GRT508BG, the AgSnO2 contacts, the 4 kV coil-to-contact barrier and the stated RoHS and IEC 62055-31 UC2 compliance still have to be verified against the real load and the real market. The shunt's resistance value, tolerance and ≤±50 ppm temperature coefficient still have to be written into the drawing. What changes is that one supplier, working from one approved drawing, becomes accountable for the joint between them.

Next step. If your meter platform is running out of board area, send the rated load, maximum switching voltage, load type, coil configuration and required shunt tolerance to GRT Relay for a drawing-based evaluation. Standard models can be sampled before a custom build is committed, and the full latching relay, current transformer and shunt range is available in the GRT Relay product catalogue (PDF).

GRT508H single-pole latching relay, a meter-oriented model listed with custom assembly options including integrated shunt
GRT508H, one of the single-pole meter relays offered with flexible wire, copper strap or integrated shunt assemblies.

Product parameters in this article are quoted from GRT Relay's published product information and are model-specific. Compliance statements are company-stated and should be confirmed against current certificates before design release.

Have Questions or Need More Details?

Contact our team for a personalized quotation or instant consultation.

Request a Quotation

Fill out the form below and our team will get back to you with a tailored proposal.

Attach images, files, or documents.

We'll respond within 24 hours (Mon–Sat).

WhatsApp Direct Chat

Prefer to chat in real-time? Message us on WhatsApp for instant assistance & quick answers.

  • Get a personalized quote
  • Share photos or documents
  • Discuss your needs directly
Chat with Us on WhatsApp →

Typically replies in 5–30 minutes during business hours.

Support: Images, videos, PDF